| Data | Value |
|---|---|
| Parts no | SN-GCJA5 |
| Product | IAQ Sensors |
| Product status | Active |
| Catalog / Datasheet | https://industrial.panasonic.com/cdbs/www-data/pdf/PLD0000/dl__ast-ind-345108.pdf |
| Type | Laser type |
| Detectable Objects&Accuracy:PM1.0 | Measurable |
| Detectable Objects&Accuracy:PM2.5 | 35~1000 : ±10% |
| Detectable Objects&Accuracy:PM10 (%) | ±10 |
| Detectable Objects&Accuracy:Pollen | × |
| Concentration range (µm/m³) | 1 - 1000 |
| Minimum detectable particle size (µm) | 0.3 |
| Life duration | 5 years (keep accuracy) |
| Size (width, depth, height) (mm) | 37×37×12 |
| Operating temperature (°C) | -70 |
| Output format | UART&I2C |
| Output | PM1.0/PM2.5/PM10 mass density (μg/m³) Number of counts by particle size (6 ranges) (pieces) Sensor status information |
| Packaging shield | Shielding function |
| Update interval / Averaging process | 1sec. / 20sec. |
| Power source (V) | 5 (Data output: 3.3V) |
| DC fan motor | Equipped |
| Operating power voltage (V) | 5.0(±10%) |
| Consumption current (mA) | Below 100 |
| Airflow control | DC fan motor |
| Maintenance (lens cleaning) | Not required |